MPK/X1

MPK/X1 Series Metallized Polypropylene Film Interference Suppression Capacitors (Class X1)

Safety classX1, across-the-line
Rated voltage330 / 440 / 480 / 500 / 530 VAC
Capacitance0.001–1.0 µF
Tolerance±10% / ±20%
Impulse test voltage4 kV (CR ≤1.0 µF)
Operating temperature−40 °C to +110 °C
UL certification markVDE certification markENEC certification markCQC certification mark

Boxed metallized polypropylene film capacitors for across-the-line EMI suppression, Class X1. Rated 330–530 VAC, 1 nF–1 µF.

Series product photograph
Series product photograph

Part numbers

153

Showing 25 of 153 part numbers

X1S1102KJ1A5100090040EV00.001±10440X1
X1S1102KN1A5130110050EVO0.001±10440X1
X1K1222KN1B0130110050EV00.0022±10530X1
X1K1332KN1B0130110050EV00.0033±10530X1
X1R1472KN1A0130110050FE00.0047±10330X1
X1R1472KN1B0130110050EV00.0047±10330X1
X1S1472KN1B0130110050EV00.0047±10440X1
X1S1472KQ1B0180110050EV00.0047±10440X1
X1R1103KJ1A5100115060EV00.01±10330X1
X1R1103KJ1B0100090040EV00.01±10330X1
X1S1103KJ130100115060EV00.01±10440X1
X1S1103KJ1A5100115060EV00.01±10440X1
X1S3103KN1A5130110050EVO0.01±10480X1
X1S3103KN1B0130110050EVO0.01±10480X1
X1S3103KQ1B0180110050EV00.01±10480X1
X1H2103KQ1A5180110050EV00.01±10500X1
X1K1103KN135130150080EV00.01±10530X1
X1K1103KN1A5130150080EV00.01±10530X1
X1S1223KJYB0130120060EV00.022±10440X1
X1S1223KN1A0130120060EV00.022±10440X1
X1S1223KN1A5130120060EV00.022±10440X1
X1S1223KQ1A5180110050EV00.022±10440X1
X1S3223KQ1B0180120060EV00.022±10480X1
X1R1333KN135130110050EV00.033±10330X1
X1S1333KJYB0130130070EV00.033±10440X1

— = not specified

Need a value that is not listed? Send us your specification.

Engineering details

Overview

Boxed metallized polypropylene film capacitors for across-the-line (L–N) EMI suppression, Class X1 to IEC / EN / UL 60384-14. Rated 330, 440, 480, 500 and 530 VAC; 1 nF–1 µF; tolerance ±10% or ±20%. Impulse test voltage 4 kV (CR ≤1.0 µF). Lead pitch 7.5–37.5 mm. Operating temperature −40 °C to +110 °C. Flame-retardant construction to UL 94 V-0.

Series features

  • Class X1 to IEC / EN / UL 60384-14 for across-the-line interference suppression where a higher impulse class than X2 is required
  • Five certified AC ratings: 330, 440, 480, 500 and 530 VAC; capacitance 1 nF–1 µF
  • Impulse test (4 kV, 24 pulses) and self-ignition test are specified
  • Six lead pitches from 7.5 to 37.5 mm
  • Boxed, resin-encapsulated metallized polypropylene construction; flame-retardant to UL 94 V-0
Specifications
Safety functionClass X1 · across-the-line (L–N) EMI suppression · higher impulse class than X2 · not for line-to-earth (Y) positions
ConstructionMetallized polypropylene film · boxed, resin-encapsulated
Reference standardsIEC / EN / UL 60384-14 · approvals to IEC 60384-14:2013 + AMD1:2016
Rated AC voltage UR330 · 440 · 480 · 500 · 530 VAC
Capacitance range0.001–1.0 µF · available values depend on rated voltage, body size, tolerance and approval scope
Capacitance tolerance±10% (K) · ±20% (M, on request)
Operating temperature−40 °C to +110 °C
Climatic category / flammability40/110/56 · passive flammability category B
Dissipation factortan δ ≤0.1%
Insulation resistance, CR ≤0.33 µF≥15,000 MΩ at 20 °C, 100 VDC, 60 s
Insulation resistance, CR >0.33 µFTime constant ≥5,000 s (T = IR [MΩ] × CN [µF]) at 20 °C, 100 VDC, 60 s
Voltage proof, terminal to terminal4.3 × UR DC, 5 s
Voltage proof, terminals to case2 × UR + 1,500 VAC, min. 2,000 VAC
Impulse test voltage4 kVDC for CR ≤1.0 µF; a test condition, not a continuous or repetitive rating
Impulse sequence24 pulses · 9 s charge / 2 s discharge cycle
Self-ignition testU~ = UR · Ui = 4.0 kV · 20 discharges of the energy-storage capacitor per sample · 5 s interval
DC operationNo continuous DC rating. VDE certificate 40054631 includes no Annex H (DC) approval.
Humidity robustnessNo biased 85/85 humidity test; the VDE approval includes no IEC 60384-14 Annex I humidity grade. For humid environments, see MPK/X1-THB.
Body dimensionsW 10–41.5 · H 11–35.5 · T 5–22.5 mm, depending on rated voltage and capacitance
Lead pitch7.5 · 10 · 15 · 22.5 · 27.5 · 37.5 mm
Lead diameter0.6 mm (pitch 7.5–10 mm) · 0.8 mm (15–37.5 mm)
Lead and packing formsLong straight · inner-bent · straight, taped · bent, taped
Taped lead spacing F7.5 / 10 / 15 / 20–22.5 mm; F = 5 mm is not offered in this series
Soldering profile, PPPreheat ≤110 °C · soldering ≤120 °C · ≤15 s
Soldering profile, PEPreheat ≤125 °C · soldering ≤160 °C · ≤15 s
Soldering profile selectionPP or PE, depending on the part number; on request
Hand soldering / reworkIron ≤350 °C · ≤3 s · ≥2 mm from the coating
Reflow solderingNot permitted; film shrinkage can degrade performance
StorageIn unopened package: ≤35 °C, ≤70% RH, ≤12 months. Keep away from corrosive gases to preserve lead solderability.
Environmental complianceRoHS and REACH compliant · code E = RoHS, F = RoHS + halogen-free
Further dataOn request: tan δ measurement conditions · voltage-proof test duration, terminals to case · impulse-circuit details · surge coordination · dry-heat life · dV/dt · current · ESR · thermal · humidity · vibration · lead strength
Variants

Ranges by dielectric, package and lead style within this series.

VariantBody dimensionsRated voltage / capacitanceConstruction / classLead / land patternNotes
J · 7.5 mmW 10 · H 11–15 · T 5–8 mm330–530 VAC · 0.001–0.0056 µFMetallized PP · X1 · K/MP 7.5 ±1.0 · d 0.6 ±0.05 mmSmallest body and lowest capacitance values.
N · 10 mmW 13 · H 11–15 · T 5–8 mm330–530 VAC · 0.001–0.01 µFMetallized PP · X1 · K/MP 10 ±1.0 · d 0.6 ±0.05 mmCompact high-voltage across-the-line filtering.
Q · 15 mmW 18 · H 11–19 · T 5–11 mm330–530 VAC · 0.01–0.068 µFMetallized PP · X1 · K/MP 15 ±1.0 · d 0.8 ±0.05 mm—
T · 22.5 mmW 26.5 · H 16.5–23 · T 7–13 mm330–530 VAC · 0.047–0.18 µFMetallized PP · X1 · K/MP 22.5 ±1.0 · d 0.8 ±0.05 mmFor repetitive mains-filter duty, check current and temperature rise.
V · 27.5 mmW 31–31.5 · H 20–28 · T 11–18 mm330–530 VAC · 0.1–0.33 µFMetallized PP · X1 · K/MP 27.5 ±1.0 · d 0.8 ±0.05 mm—
L · 37.5 mmW 41.5 · H 28–35.5 · T 14–22.5 mm330–530 VAC · 0.39–1.0 µFMetallized PP · X1 · K/MP 37.5 ±1.0 · d 0.8 ±0.05 mmLargest body. Verify mechanical fixing, vibration and hot-spot temperature.
Selection guide

Start with the circuit position: Class X1 is an across-the-line class for higher impulse stress and is not interchangeable with X2 or Y capacitors. Then define the certified AC voltage, capacitance, surge and impulse requirements, body size, humidity profile and assembly process.

  1. Confirm the X1 circuit position

    Use X1 across line conductors where the equipment standard and overvoltage category require its higher impulse class. Do not use it as a line-to-earth Y capacitor, and do not substitute X2 without checking insulation and surge requirements.

  2. Match the AC voltage approval

    Select 330, 440, 480, 500 or 530 VAC and the approval marks the end equipment needs.

  3. Coordinate surge and repetitive stress

    The 4 kV / 24-pulse impulse sequence is a test condition, not an application surge rating. Define waveform, source impedance, peak current and repetition for the equipment, and coordinate surge protection at equipment level.

  4. Set capacitance, losses, current and mission profile

    Choose capacitance for the required EMI attenuation. Then verify losses, RMS and peak current, self-heating, derating over frequency and temperature, dry-heat life and humidity performance. The AC rating alone does not define any of these.

  5. Specify geometry and assembly process

    Specify W/H/T, pitch, lead diameter and form and packing for each capacitance and voltage. Use the soldering profile of the selected part, check PCB spacing and do not reflow-solder.

Approvals & reliability

Approvals & qualifications

CQC, VDE/ENEC, IECEE CB and UL/cUL approvals cover MPK X1 capacitors from 1 nF to 1 µF at 330–530 VAC. The approvals include neither DC use (Annex H) nor an Annex I humidity grade.

AgencyStandardCertificateScope
CQC certification markCQCIEC 60384-14:2013 + AMD1:2016CQC22001337767MPK X1, 0.001–1.0 µF, 330/440/480/500/530 VAC, ±10% (K) or ±20% (M). Issued 7 Apr 2022.
VDE certification markENEC certification markVDE / ENECEN 60384-14:2013 + A1:201640054631MPK X1, 0.001–1.0 µF, 330/440/480/500/530 VAC, K/M, climatic category 40/110/56, passive flammability category B. No Annex H (DC) approval; no Annex I humidity grade.
IECEE CB scheme markIECEE CBIEC 60384-14:2013 + AMD1:2016DE1-65967MPK X1, 1 nF–1 µF, K/M, 330/440/480/500/530 VAC, 40/110/56/B. Test report 288316-TL3-1.
UL certification markUL / cULUL 60384-14E208107MPK X1, 0.001–1.0 µF, 330/440/480/500/530 VAC, −40 to +110 °C, tolerance K/M.

Each certificate covers the types and ratings listed on it.

Reliability tests

Initial characteristics cover dissipation factor, insulation resistance and voltage proof. Impulse and self-ignition test sequences are specified at 4 kV.

TestConditionAcceptance
Impulse test4 kVDC · 24 pulses · 9 s charge / 2 s dischargeTest circuit, waveform and post-test limits on request
Self-ignition testU~ = UR · Ui = 4.0 kV · 20 discharges per sample · 5 s intervalTest energy and pass criteria on request
Voltage proofTerminal to terminal: 4.3 × UR DC, 5 s. Terminals to case: 2 × UR + 1,500 VAC, min. 2,000 VACTest duration and pass criteria on request
Design notes

Use X1 between line conductors

Use between line conductors where the required impulse class and the equipment standard allow the part. An X1 capacitor is not a line-to-earth Y capacitor and does not replace reinforced insulation.

Rated voltage is not a surge rating

330–530 VAC is the certified continuous AC rating. The 4 kV impulse test is a test condition, not a continuous or repetitive rating. Coordinate installation category, mains transients and equipment surge tests with the impulse test circuit and acceptance criteria.

Control loss, current and hot-spot temperature

Design with tan δ versus frequency and temperature, RMS and peak current, ESR and thermal resistance of the selected part. Validate normal, brownout, harmonic and repetitive transient operation in the final enclosure.

No THB rating

This series has no biased 85/85 humidity rating, and its VDE approval includes no humidity grade. For humid environments, select MPK/X1-THB and design to its own ratings.

Assembly

Specify body size, pitch, lead form, packing and soldering profile for each part number. Do not reflow-solder. Validate PCB spacing, cleaning, coating and vibration in the application.

Part numbering

Example ordering code. Not every combination is available.

X1 · S1 · 104 · K · Q · 1 · B0 · 180 · 120 · 060 · E · V · 0

CodeMeaning
X1Safety class X1 (across-the-line) and series
S1Rated voltage: S1 = 440 VAC; R1 = 330, S3 = 480, H2 = 500, K1 = 530 VAC
104Capacitance code: 104 = 100 nF
KCapacitance tolerance: K = ±10%; M = ±20%
QLead pitch: Q = 15 mm; J = 7.5, N = 10, T = 22.5, V = 27.5, L = 37.5 mm
1Lead form: 1 = long straight; 2 = inner-bent, 5 = straight taped, 6 = bent taped
B0Lead length: B0 = 20.0 mm
180Body width: 180 = 18.0 mm
120Body height: 120 = 12.0 mm
060Body thickness: 060 = 6.0 mm
EEnvironmental: E = RoHS; F = RoHS + halogen-free
VCase color: V = blue; E = gray
0STE internal management code